{"id":466,"date":"2023-10-02T12:13:00","date_gmt":"2023-10-02T09:13:00","guid":{"rendered":"https:\/\/folter.tech\/?post_type=product&#038;p=466"},"modified":"2023-10-02T12:13:01","modified_gmt":"2023-10-02T09:13:01","slug":"fsv","status":"publish","type":"product","link":"https:\/\/folter.tech\/en\/product\/ochistka-ventiljacionnyh-vybrosov\/fsv\/","title":{"rendered":"FSV type filters for purifying compressed air from aerosol impurities"},"content":{"rendered":"<p>A positive effect is achieved by removing water-oil mist and solid particles larger than 0.3 microns from the air with an efficiency of up to 99.95%, which ensures purity classes 1&#8230;0 according to GOST 17433-80 \u201cIndustrial purity.\u00a0Compressed air.\u00a0Pollution classes.\u201d\u00a0Pre-filter for compressed air FSV-P is designed to remove the bulk of large particles from compressed air.\u00a0Almost completely captures particles (solid and liquid) larger than 5 microns.\u00a0It is recommended to install after the compressor end cooler and after the receiver;\u00a0in pneumatic systems that do not require a large amount of contamination;\u00a0before more efficient filters such as FSV-O.<\/p>\n<p>The main compressed air filter FSV-O is designed to remove the bulk of liquid and solid contaminants from compressed air.\u00a0Completely captures particles larger than 1 micron.\u00a0The degree of purification of oil mist with a droplet size of 0.3 microns is 98&#8230;99%).\u00a0It is recommended to use it before refrigeration and absorption drying units, in simple pneumatic systems, and before highly efficient FSV-T filters.\u00a0The FSV-T fine compressed air filter is designed to completely remove liquid and solid contaminants from compressed air.<\/p>\n<p>Completely captures particles larger than 0.3 microns.\u00a0The degree of purification of oil mist with a droplet size of 0.3 microns is 99.95%.\u00a0Recommended for use in pneumatic systems critical to the presence of liquid oil in compressed air, as an alternative to a \u201cdry compressor\u201d;\u00a0in front of activated carbon adsorbers that remove oil vapor from the air;\u00a0in precision pneumatic equipment and robotics;\u00a0in high-precision instrumentation pneumatic systems;\u00a0in air motors;\u00a0when applying paint and varnish coatings by spraying;\u00a0when working with pneumatic tools in enclosed spaces;\u00a0in the food and pharmaceutical industries.<\/p>\n<h4>Technical characteristics of filters<\/h4>\n<table>\n<tbody>\n<tr>\n<th>Type<\/th>\n<td>FSV-P FSV-O FSV-T<\/td>\n<\/tr>\n<tr>\n<th>Maximum operating pressure (excess), MPa (kg\/cm2)<\/th>\n<td>0.8 (8)<\/td>\n<\/tr>\n<tr>\n<th>Maximum operating temperature, 0C<\/th>\n<td>+60<\/td>\n<\/tr>\n<tr>\n<th>Minimum temperature of purified air, 0C<\/th>\n<td>+5<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Hydraulic resistance of the filter, kPa (kg \/ cm 2)<\/th>\n<\/tr>\n<tr>\n<th>clean dry<\/th>\n<td>1 (0.01) 2 (0.02) 4 (0.04)<\/td>\n<\/tr>\n<tr>\n<th>rich in oil<\/th>\n<td>3 (0.03) 15 (0.15) 30 (0.3)<\/td>\n<\/tr>\n<tr>\n<th>maximum before replacing filter elements<\/th>\n<td>60 (0.6) *<\/td>\n<\/tr>\n<tr>\n<th>Approximate service life of filter elements before replacement, h<\/th>\n<td>3000**<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*In FSV-P filters, only the filter material can be replaced.<br \/>\n** The main filter FSV-O must be used in conjunction with a pre-filter FSV-P or another device for pre-cleaning compressed air with similar characteristics.\u00a0The highly efficient fine filter FSV-T can only be used in conjunction with the main FSV-O.<\/p>\n<h4>Basic filter parameters<\/h4>\n<table>\n<tbody>\n<tr>\n<th rowspan=\"4\">Options<\/th>\n<th colspan=\"6\">Filter brand FSV<\/th>\n<\/tr>\n<tr>\n<th>P-60<\/th>\n<th>P-140<\/th>\n<th>P-280<\/th>\n<th>P-560<\/th>\n<th>P-1700<\/th>\n<th>P-3400<\/th>\n<\/tr>\n<tr>\n<th>O-60<\/th>\n<th>O-140<\/th>\n<th>O-280<\/th>\n<th>O-560<\/th>\n<th>O-1700<\/th>\n<th>O-3400<\/th>\n<\/tr>\n<tr>\n<th>T-60<\/th>\n<th>T-140<\/th>\n<th>T-280<\/th>\n<th>T-560<\/th>\n<th>T-1700<\/th>\n<th>T-3400<\/th>\n<\/tr>\n<tr>\n<th>Air flow, m3\/h (m3\/min)<\/th>\n<td>60 (1.0)<\/td>\n<td>140 (2.3)<\/td>\n<td>280 (4.7)<\/td>\n<td>560 (9.3)<\/td>\n<td>1700 (28.3)<\/td>\n<td>3400 (56.6)<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"2\">Conditional bore, mm<\/th>\n<th colspan=\"4\">union<\/th>\n<th colspan=\"2\">flange<\/th>\n<\/tr>\n<tr>\n<td>Dy = 15<\/td>\n<td>Dy = 32<\/td>\n<td>Dy = 32<\/td>\n<td>Dy = 50<\/td>\n<td>Dy = 65<\/td>\n<td>Dy = 100<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"3\">Item type<\/th>\n<td>EP-52100<\/td>\n<td>EP-125<\/td>\n<td>EP-250<\/td>\n<td>EP-500<\/td>\n<td>EP-500<\/td>\n<td>EP-500<\/td>\n<\/tr>\n<tr>\n<td>EO-52100<\/td>\n<td>EO-125<\/td>\n<td>ET-250<\/td>\n<td>EO-500<\/td>\n<td>EO-500<\/td>\n<td>EO-500<\/td>\n<\/tr>\n<tr>\n<td>ET-52100<\/td>\n<td>ET-125<\/td>\n<td>ET-250<\/td>\n<td>ET-500<\/td>\n<td>ET-500<\/td>\n<td>ET-500<\/td>\n<\/tr>\n<tr>\n<th colspan=\"7\">Overall dimensions of filter elements, mm:<\/th>\n<\/tr>\n<tr>\n<th>height<\/th>\n<td>100<\/td>\n<td>125<\/td>\n<td>250<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<th>external diameter<\/th>\n<td>50<\/td>\n<td>74<\/td>\n<td>74<\/td>\n<td>74<\/td>\n<td>74<\/td>\n<td>74<\/td>\n<\/tr>\n<tr>\n<th>inner diameter<\/th>\n<td>20<\/td>\n<td>35<\/td>\n<td>35<\/td>\n<td>35<\/td>\n<td>35<\/td>\n<td>35<\/td>\n<\/tr>\n<tr>\n<th>Number of elements<\/th>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>3<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<th colspan=\"7\">Overall dimensions, mm<\/th>\n<\/tr>\n<tr>\n<th>height<\/th>\n<td>156<\/td>\n<td>393<\/td>\n<td>518<\/td>\n<td>768<\/td>\n<td>865<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th>diameter<\/th>\n<td>106<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>220<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th>width<\/th>\n<td>225<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>420<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th>Weight, kg<\/th>\n<td>2.3<\/td>\n<td>5.2<\/td>\n<td>6.5<\/td>\n<td>9.2<\/td>\n<td>28.0<\/td>\n<td>62.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Air flow through filters, normalized to 200 C and atmospheric pressure, is indicated for a working pressure of 0.7 MPa (7 kg \/ cm2)<\/p>\n<p>To determine the air flow rate at an operating pressure other than 0.7 MPa (7 kg\/cm2), the value indicated in the table must be multiplied by the flow coefficient.<\/p>\n<table>\n<tbody>\n<tr>\n<th rowspan=\"2\">Working pressure,<br \/>\nMPa (kg\/cm3)<\/th>\n<td>0.1<\/td>\n<td>0.2<\/td>\n<td>0.3<\/td>\n<td>0.4<\/td>\n<td>0.5<\/td>\n<td>0.6<\/td>\n<td>0.7<\/td>\n<td>0.8<\/td>\n<td>0.9<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>(1)<\/td>\n<td>(2)<\/td>\n<td>(3)<\/td>\n<td>(4)<\/td>\n<td>(5)<\/td>\n<td>(6)<\/td>\n<td>(7)<\/td>\n<td>(8)<\/td>\n<td>(9)<\/td>\n<td>(10)<\/td>\n<\/tr>\n<tr>\n<th>Flow coefficient<\/th>\n<td>0.36<\/td>\n<td>0.49<\/td>\n<td>0.6<\/td>\n<td>0.71<\/td>\n<td>0.81<\/td>\n<td>0.9<\/td>\n<td>1.0<\/td>\n<td>1.08<\/td>\n<td>1.1<\/td>\n<td>1.25<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Filters for purifying compressed air FSV increase the reliability and service life of pneumatic equipment, machines and tools;\u00a0improve the quality of paint and varnish coatings obtained by pneumatic spraying;\u00a0provide more reliable and economical operation of air drying units;\u00a0improve the quality of products in the manufacturing process of which compressed air is used;\u00a0increase the service life of bag filters with pulse regeneration.<\/p>\n","protected":false},"featured_media":467,"template":"","meta":{"inline_featured_image":false},"product_cat":[16],"product_tag":[],"class_list":["post-466","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-ochistka-ventiljacionnyh-vybrosov"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product\/466","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/media\/467"}],"wp:attachment":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/media?parent=466"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product_cat?post=466"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product_tag?post=466"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}