{"id":513,"date":"2023-10-02T14:54:57","date_gmt":"2023-10-02T11:54:57","guid":{"rendered":"https:\/\/folter.tech\/?post_type=product&#038;p=513"},"modified":"2023-10-02T14:54:57","modified_gmt":"2023-10-02T11:54:57","slug":"dnmpdt","status":"publish","type":"product","link":"https:\/\/folter.tech\/en\/product\/dopolnitelnoe-oborudovanie\/dnmpdt\/","title":{"rendered":"Differential pressure gauges and pressure sensors"},"content":{"rendered":"<p><\/p>\n<h4>Technical characteristics of pressure gauges type DPG<\/h4>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<th>measurement range<\/th>\n<\/tr>\n<tr>\n<td>DPG600<\/td>\n<td>0-600 Pa<\/td>\n<\/tr>\n<tr>\n<td>DPG800<\/td>\n<td>0-800 Pa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Technical characteristics of PS type sensors<\/h4>\n<table>\n<tbody>\n<tr>\n<th>Model code 5A &#8211; microsensor<\/th>\n<th>Pressure range<\/th>\n<th>Sensor difference<\/th>\n<th>Sensor accuracy.\u00a0Low pressure model<\/th>\n<th>Sensor accuracy.\u00a0High pressure model<\/th>\n<th>Calculated electrical\u00a0power\u00a0Resist.\u00a0load<\/th>\n<th>Calculated electrical\u00a0power\u00a0Induct.\u00a0load<\/th>\n<\/tr>\n<tr>\n<td>PS600 (-5A)<\/td>\n<td>40\u2026600 Pa<\/td>\n<td>30 Pa<\/td>\n<td>\u00b15 Pa<\/td>\n<td>\u00b130 Pa<\/td>\n<td>3A\/250VAC*)<\/td>\n<td>2A\/250VAC<\/td>\n<\/tr>\n<tr>\n<td>PS1500 (-5A)<\/td>\n<td>100\u20261500 Pa<\/td>\n<td>80 Pa<\/td>\n<td>\u00b110 Pa<\/td>\n<td>\u00b150 Pa<\/td>\n<td>3A\/250VAC*)<\/td>\n<td>2A\/250VAC<\/td>\n<\/tr>\n<tr>\n<td>PS4500<\/td>\n<td>500\u20264500 Pa<\/td>\n<td>180 Pa<\/td>\n<td>\u00b150 Pa<\/td>\n<td>\u00b1200 Pa<\/td>\n<td>5A\/250VAC<\/td>\n<td>2A\/250VAC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The DPG pressure gauge and the PS sensor are connected to two fittings of the filter chambers before and after the filter using flexible hoses (tubes) and allow visual monitoring (DPG pressure gauge) of changes in the resistance (pressure drop) of the filters, and with the help of an electronic PS sensor, a signal about the achievement of a given pressure drop can be output as an electrical signal.\u00a0For visual monitoring of filter resistance, liquid inclined manometers type MM and vertical type MMK can also be used.<\/p>\n<h4>Technical characteristics of pressure gauges type MM and MMK<\/h4>\n<table>\n<tbody>\n<tr>\n<th>Model code<\/th>\n<th>measurement range<\/th>\n<th>Accuracy<\/th>\n<th>Model code<\/th>\n<th>measurement range<\/th>\n<th>Accuracy<\/th>\n<\/tr>\n<tr>\n<td>MM200600<\/td>\n<td>0\u2026600Pa<\/td>\n<td>5 Pa\/25 Pa<\/td>\n<td>MM1K<\/td>\n<td>0\u20261.0 kPa<\/td>\n<td>10 Pa<\/td>\n<\/tr>\n<tr>\n<td>MM100*)<\/td>\n<td>0\u20261500 Pa<\/td>\n<td>10 Pa\/50 Pa<\/td>\n<td>MM1.5K<\/td>\n<td>0\u20261.5 kPa<\/td>\n<td>10 Pa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>If it is necessary to visually monitor the resistance of filters with the simultaneous supply of an electrical signal about a change in resistance, combined models of filter controller devices can be used.<\/p>\n<h4>Technical characteristics of filter controllers type MM\/PS and DPG\/PS<\/h4>\n<table>\n<tbody>\n<tr>\n<th>Model code<\/th>\n<th>Pressure gauge range<\/th>\n<th>Pressure gauge range<\/th>\n<th>Sensor difference<\/th>\n<th>Sensor accuracy. Low pressure model<\/th>\n<th>Sensor accuracy.High pressure model<\/th>\n<\/tr>\n<tr>\n<td>MM200600\/PS600(red gauge fluid)<\/td>\n<td>0\u2026600 Ra<\/td>\n<td>40\u2026600 Ra<\/td>\n<td>30 Ra<\/td>\n<td>\u00b15 Ra<\/td>\n<td>\u00b130 Ra<\/td>\n<td>\u00b150 Ra<\/td>\n<\/tr>\n<tr>\n<td>MM551500\/PS1500 (blue gauge fluid)<\/td>\n<td>0\u20261500 Ra<\/td>\n<td>100\u20261500 Ra<\/td>\n<td>80 Ra<\/td>\n<td>10 Ra<\/td>\n<td>10 Pa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Model code<\/th>\n<th>Pressure gauge range<\/th>\n<th>Sensor range<\/th>\n<th>Pressure gauge accuracy at temp.\u00a020C<\/th>\n<th>Sensor difference<\/th>\n<th>Sensor accuracy.\u00a0Low pressure model<\/th>\n<th>Sensor accuracy.\u00a0High pressure model<\/th>\n<\/tr>\n<tr>\n<td>DPG600\/PS600<\/td>\n<td>0\u2026600 Ra<\/td>\n<td>40\u2026600 Ra<\/td>\n<td>\u00b12%<\/td>\n<td>30 Ra<\/td>\n<td>40Ra\u00b15 Ra<\/td>\n<td>600Ra\u00b130 Ra<\/td>\n<\/tr>\n<tr>\n<td>DPG1.5K\/PS1500<\/td>\n<td>0\u20261500 Ra<\/td>\n<td>100\u20261500Pa<\/td>\n<td>\u00b12%<\/td>\n<td>80 Ra<\/td>\n<td>100Ra\u00b110 Ra<\/td>\n<td>1500Ra\u00b150 Ra<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additionally, all pressure gauges and sensors can be equipped with plastic fittings for installation in the walls of the filter chambers and after the filter and flexible tubes 2 m long.<\/p>","protected":false},"excerpt":{"rendered":"<p>Differential pressure gauges of the DPG type and electronic pressure sensors of the PS type are designed to measure excess, vacuum pressure, as well as the difference in pressure of air and non-aggressive gases and can be used to monitor the resistance of air filters in sections of pocket filters of the SKF type;\u00a0pleated filters type SSF, in air distribution modules type MV, as well as in any other filter chambers.<\/p>\n","protected":false},"featured_media":514,"template":"","meta":{"inline_featured_image":false},"product_cat":[18],"product_tag":[],"class_list":["post-513","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-dopolnitelnoe-oborudovanie"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product\/513","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/media\/514"}],"wp:attachment":[{"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/media?parent=513"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product_cat?post=513"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/folter.tech\/en\/wp-json\/wp\/v2\/product_tag?post=513"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}